20% OFF shipping at svevole.cz on orders over $79 + up to 10% OFF products
svevole.cz
home > Fluke 62 Max IR Thermometer (Pre-Owned) > Fluke 62 Max IR Thermometer (Pre-Owned)
download picture
Fluke 62 Max IR Thermometer (Pre-Owned)Fluke 62 Max IR Thermometer (Pre Owned) Key Features At A Glance Temperature range from 30 C to 500 C on the 62 Max and 30 C to 650 C on the 62 Max+ 10: 1 optical resolution on the 62 Max and 12: 1 on the 62 Max+ (calculated at 90% energy) IP54 rated for dust and water resistance Drop tested to 3 meters (9. 8 feet) Spectral response 8 to 14 microns with adjustable emissivity from 0. 10 to 1. 00 Dual rotating lasers on the 62 Max+ identify the
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Fluke 62 Max IR Thermometer (Pre-Owned)

Key Features At A Glance

  • Temperature range from -30 °C to 500 °C on the 62 Max and -30 °C to 650 °C on the 62 Max+
  • 10:1 optical resolution on the 62 Max and 12:1 on the 62 Max+ (calculated at 90% energy)
  • IP54 rated for dust and water resistance
  • Drop-tested to 3 meters (9.8 feet)
  • Spectral response 8 to 14 microns with adjustable emissivity from 0.10 to 1.00
  • Dual rotating lasers on the 62 Max+ identify the measurement area between the dots
  • Min/Max/Avg/Dif display modes plus Hi/Lo alarms for out-of-limit measurements
  • Single AA battery operation with large backlit display

The Fluke 62 Max is a handheld infrared thermometer designed for non-contact temperature measurement in electrical, mechanical, and HVAC environments. As the printed datasheet describes, the instrument is small in size, IP54 rated for dust and water resistance, and drop-tested to 3 meters — engineered to be handled on the job without special care. The series is offered in two models: the 62 Max covering -30 °C to 500 °C with 10:1 optical resolution, and the 62 Max+ covering -30 °C to 650 °C with 12:1 optical resolution and dual rotating lasers.

The datasheet identifies the instrument's role in detecting potential problems in electrical and mechanical applications, where temperature is often the first indication of a developing fault. Specific applications named on the page include identifying hot spots in electrical panels, finding overheating motors, and assessing HVAC system efficiency. The non-contact measurement format allows readings in hard-to-reach or hazardous areas where contact thermometry is impractical, supporting early detection and correction of abnormal temperatures.

Compare Other Models in This Series

The Fluke 62 Max series consists of two handheld infrared thermometer models — the 62 Max and the 62 Max+ — built on a shared rugged platform. Both share the IP54 dust and water resistance rating, the 3-meter drop-test specification, the 8 to 14 micron spectral response, the 0.10 to 1.00 emissivity range, the 0.1 °C display resolution, and the single AA battery power format.

The two models differ in measurement performance: temperature range, accuracy, response time, optical resolution, and repeatability all step up on the 62 Max+, which also adds dual rotating lasers for measurement-area identification. The comparison table below lays out the printed specifications for each model side by side.

Each pre-owned 62 Max series model below is presented on its own product page with pricing matched to its condition. Click through to the specific model and condition that fits your application and budget.

The 62 Max+ extends the upper measurement limit to 650 °C versus 500 °C on the 62 Max — a meaningful difference for applications involving higher-temperature mechanical components, exhaust systems, or industrial process equipment. The 62 Max+ also tightens the basic accuracy from ±1.5% of reading to ±1.0% of reading and improves repeatability from ±0.8% (or <±1.0 °C) to ±0.5% (or <±0.5 °C), making it the choice when measurement confidence at the recorded value matters more.

The 62 Max+ delivers a faster response time at <300 ms to 95% of reading versus <500 ms on the 62 Max, and a 12:1 optical resolution versus 10:1 — allowing the 62 Max+ to measure smaller targets at the same distance, or the same target size at greater distance. The dual rotating lasers on the 62 Max+ bracket the measurement spot between the two laser dots, which is an operator-facing aid the base 62 Max does not include. See the per-model comparison table for the full specification breakdown.

Model Temperature Range Accuracy Optical Resolution
62 Max -30 °C to 500 °C (-22 °F to 932 °F) ± 1.5 °C or ± 1.5 % of reading 10:1 (calculated at 90 % energy)
62 Max+ -30 °C to 650 °C (-22 °F to 1202 °F) ± 1.0 °C or ± 1.0 % of reading 12:1 (calculated at 90 % energy)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification 62 Max 62 Max+
Temperature Range -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ± 1.5 °C or ± 1.5 % of reading; ± 2.0 at -10 °C to 0 °C; ± 3.0 at -30 °C to -10 °C ± 1.0 °C or ± 1.0 % of reading; ± 2.0 at -10 °C to 0 °C; ± 3.0 at -30 °C to -10 °C
Response Time (95 %) <500 ms (95 % of reading) <300 ms (95 % of reading)
Spectral Response 8 to 14 microns 8 to 14 microns
Emissivity 0.10 to 1.00 0.10 to 1.00
Optical Resolution 10:1 (calculated at 90 % energy) 12:1 (calculated at 90 % energy)
Display Resolution 0.1 °C (0.2 °F) 0.1 °C (0.2 °F)
Repeatability of Readings ± 0.8 % of reading or <± 1.0 °C (2 °F), whichever is greater ± 0.5 % of reading or <± 0.5 °C (1 °F), whichever is greater
Power AA battery AA battery
Dust and Water Resistance IP54 rated IP54 rated
Drop Tested 3-meter (9.8-foot) 3-meter (9.8-foot)
Lasers Single laser Dual rotating lasers
Important: Accuracy specifications widen at lower ambient temperatures: ±2.0 at -10 °C to 0 °C and ±3.0 at -30 °C to -10 °C on both 62 Max and 62 Max+.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Fluke 62 Max IR Thermometer (Pre-Owned)

Item no : 30678875305
sold recently : Login >>
US$ 114.99
Pay in 4 interest-free payments of $28.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 114.99

1-11

US$ 103.49

12-35

US$ 80.49

36-59

US$ 68.99

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches